Share This Article

 Classification of the Power Transformer

Electric Treasure for the  Power Distribution Transformers

S13-M Distribution Transformer

  Number of Phase

  • Single-Phase Transformer: Used for single-phase load and three-phase transformer group.
  • Three-Phase Transformer: Used for three-phase system the rise and fall of voltage.

 Cooling Way

  • Dry Type Transformer: rely on the natural air convection cooling or increase the cooling fan, used in high-rise buildings, more high-speed toll site and local lighting electricity, electronic circuit and other small capacity transformer. Such as: SCB10, SCB11 Series.
  • Oil-Immersed Transformer: Rely on oil as cooling medium, such as oil-immersed natural cooling and oil-immersed forced-air cooling, oil immersion cooling, forced oil circulation, etc. Such as: S11, / S13 – M Series.

 Use

  • Power Transformer: Used for the rise and fall of voltage transmission and distribution system.
  • Instrument Transformer: Such as voltage transformer, current transformer, used for measuring instrument and relay protection device.
  • Test Transformer: Can produce high voltage, electrical equipment for high voltage test.
  • Special Transformer, such as electric furnace transformer, rectifier transformer, adjust transformer, capacitor, phase shifting transformer, etc.
    Winding Form
  • Double Winding Transformer: Used to connect two voltage grade of power system.
  • Three Winding Transformer: generally used in the regional power system transformer substation, connecting the three voltage levels.
  • The Self Coupling Transformer: Used to connect to different voltage of power system. Also can be used as ordinary booster or fall after the transformer.

 Core Form

  • Core Transformer: Used for high voltage power transformer.
  • Amorphous Alloy Transformer: Amorphous alloy iron core transformer is to use new magnetic materials, no-load current fell about 80%, energy saving effect is ideal distribution transformer, especially suitable for rural power grids and developing regions such as load rate is low.
  • Shell Type Transformer: Used for large current special transformer, such as the electric furnace transformer, electric welding transformer; Or used in electronic instruments, TV, radio power transformer, etc.

 Characteristic Parameter

  • SCB10-Series-Working Frequency: Because of the large transformer core loss and frequency relations should be used according to the frequency to design and use of the frequency according to the working frequency.
  • Power Rating: Under the rules of frequency and voltage transformer can work for a long time, but not in excess of the prescribed temperature rise of output power.
  • Rated Voltage: Refers to on the transformer coil voltage is allowed, work shall not be greater than the specified value.
  • Voltage Than: Refers to the transformer primary voltage and the ratio of secondary voltage, no-load voltage ratio and the load voltage ratio of the difference.
  • No-Load Current: Transformer secondary open-circuit, primary still has certain current, this part of the current called the no-load current. No-load current from magnetizing current (flux) and iron loss current (caused by core loss).For 50 Hz power supply transformer no-load current basically equal to the magnetizing current.
  • No-Load Loss: Refers to the transformer secondary open-circuit, measured in primary power loss. The main loss is the core loss, followed by the no-load current on the primary coil copper resistance loss (copper loss), this part of the loss is very small.
  • Efficiency: Refers to the secondary power P2 and P1 ratio is the percentage of primary power. Usually transformer rated power is larger, the higher the efficiency.
  • Insulation Resistance: Said transformer various between coils, each coil and iron core insulation performance. The discretion of the insulation resistance and insulating materials used by performance, degree of temperature and humidity.

Everything is in Electrical Treasure!